Calculation of the power of the air conditioner for the production room

Many modern instruments and equipment are very sensitive to changes in temperature or humidity. To ensure their normal operation, special air conditioning systems are installed in production facilities, which are complex multi-module structures.

What is SLE of industrial premises

More doesn't mean better
More doesn't mean better

Air conditioning systems in industrial premises (SCR) are necessary to ensure the necessary parameters of air in industrial premises. Indoor air conditioning is provided with ventilation, and sometimes with heating. However, the most advanced systems can handle all three functions.

According to construction companies, about 15% of the funds spent on the construction of data centers and enterprises with complex technological processes go to the organization of air conditioning in the premises.
Modern air conditioning of production facilities is an expensive task, which takes up to 60% of the funds used to maintain the building.

Air conditioning power calculation

The calculation of air conditioning implies that for 1 square. a meter of floor space accounts for 2.5 kW of power of a precision air conditioner.

That is 2.5 times higher than the rated capacity of a domestic air conditioner.

Domestic or “comfortable” air conditioners have a coefficient of perceptible cold of 0.65 - 0.7. The remaining 0.3 or 30% of the power is used to drain the air in the room. After all, people emit a lot of moisture.

But the technique does not distinguish it at all. Therefore, the coefficient of perceptible cold in precision air conditioners is 0.8 - 0.95.

An equally important parameter of air conditioning is the ability to maintain a given temperature level. Precision air conditioning systems for industrial premises maintain the temperature with an accuracy of 2 degrees, and some even up to 0.5 degrees. Most comfortable air conditioners provide for temperature drops of up to 5 degrees.

The most important climatic parameter, taken into account when calculating the conditioning of rooms and necessary for the normal operation of precision equipment, is humidity. Precision climate systems are able to maintain this indicator at the level required in each case, on average it is 44 - 55%.

Owners who save on professional air conditioning, sooner or later encounter breakdowns of expensive equipment: the contacts oxidize, the printed circuit boards crack, the insulation of the wiring dries. The equipment requires complex and expensive repairs.

Heating

Ventilation

Sewerage