Decoding error codes and troubleshooting SAMSUNG air conditioners

Air conditioners SAMSUNG equipped with a developed self-diagnosis system, as a result of which the control system, when a certain malfunction is detected, blocks the operation of this unit, while simultaneously informing the user about the cause of the breakdown.

You can fix the errors of the air conditioners using the appropriate instructions for decoding the malfunctions.

Samsung air conditioner error - troubleshooting

Normal Samsung Air Conditioner
Normal Samsung Air Conditioner

Some models of this unit from Samsung are equipped with a text mode, to enter which you need to hold the “Enable” button for five seconds, located on the internal unit of this device.

The air conditioning control system reports an error due to the blinking LED on the panel of the indoor unit. In the presence of a certain error of Samsung air conditioners, the LEDs blink or light in the set sequence. If the control system of this unit has detected more than one fault, then the fault is initially indicated with the highest priority, and only then the rest.

Main error codes for Samsung air conditioners

As soon as the samsung air conditioner error is detected, it is displayed on the screen:

  • EEPROM is an auxiliary memory error. It is displayed only for models that have a resume function when there is a power outage;
  • Error measuring the temperature indicator of the indoor unit;
  • If the speed does not exceed 450 rpm for 15-20 seconds, then the samsung air conditioner error code is issued, the decryption of which informs the user about the malfunction of the fan speed of the indoor unit;
  • Error measuring the temperature of the heat exchanger of the indoor unit;
  • When a function is installed or an error occurs, this result is displayed on the screen in the form of an appropriate code.

The full list of Samsung air conditioning errors is as follows.

A complete list of samsung air conditioner error codes
A complete list of samsung air conditioner error codes

When testing the operation of this unit for malfunctions, the cooling mode is activated with the following restrictions:

  • Forced operation of the compressor in cooling mode in the absence of shutdown / on, taking into account the temperature set inside. In this case, there is no defrosting mode;
  • When rotating the internal fan at high speed;
  • The circulation of the air flow up and down due to the modes of operation of the blade.

The test mode requires the introduction of a cooling mode that operates, regardless of the internal or set temperature.

Before installing such a unit, the user must read the operating instructions for this equipment in detail. Error codes of air conditioners also need to be studied and decoded in detail.

Heating

Ventilation